SMART BMS Solution
MoPEC offers end-to-end expertise in battery management systems (BMS), covering design, hardware/software development, prototyping, performance testing, and certification.
Specifically, we are promoting the development of a reliable and efficient BMS, built on active cell balancing, protection circuitry, condition monitoring, and communication interface technologies.
Backed by broad industry experience and technical expertise, we continue to set ourselves apart with BMS solutions customized to our customers’ needs.
-
- Over-current protection
- It disconnects power when the current exceeds a specified limit, protecting both the battery and the protective circuitry from damage.
-
- Over-temperature protection circuit
- Cutoff voltage triggered by temperature rise due to extended charging
-
- Short-circuit cutoff
- Power is cutoff in advance to prevent damage to the battery or protective circuits and reduce the risk of fire.
-
- Over-discharge protection
- Prevents voltage from dropping too low, protecting the electrode from permanent damage due to prolonged over-discharge.
-
- Over-charge protection
- in the event of overcharging, a chemical reaction inside the cell prevents excessive gas and heat generation.
-
- Applied with Active Valancing
- Maintain cells in top condition through automatic adjustment to prevent permanent electrode damage that would reduce lifespan